Application Value of Spiral CT Pulmonary Angiography with Low Radiation Dose and Low Dose Contrast Agent |
XIE Hui, QIN Chuan, DENG Xiaolin, et al |
Dazu County District People's Hospital in Chongqing, Chongqing Dazu 402360, China |
|
|
Abstract Objective: To investigate the application value of spiral CT pulmonary angiography with low radiation dose and low dose contrast agent. Methods: Fifty-six patients received spiral CT pulmonary angiography in our hospital from May 2015 to May 2016 were selected as the research objects. All of the patients were randomly assigned into routine scan group (n=28) and double low dose scan group (n=28). Toshiba ONE Aquilion 320 slice spiral CT was used to check, the routine scan group (120kv, Omnipaque 350mgI/ml), the double low dose scan group (100kV, Visipaque 270mgI/ml), the other parameters were the same. The following parameters of two groups were compared: the CT values of each segment of the pulmonary artery, the values of noise, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), the quality of the pictures, the CT dose index (CTDIvol), dose length product (DLP), effective radiation dose (ED) and iodine intake. Results: The CT values of each segment of the pulmonary artery of two groups had no significant difference (P>0.05). The values of SD [(7.7±2.1) vs (8.3±2.4)], SNR [ (23.9±7.3) vs (25.1±7.8)], CNR[(24.9±6.6) vs (27.1±7.2)], and the scores of picture quality [(4.1±0.8) vs (3.8±0.8)] of two groups had no difference (P<0.001). The CTDIvol [(6.1±0.4) vs (8.4±0.6)mGy], DLP [(293.4±21.7) vs (391.5±33.2) mGy.cm], ED [(4.3±0.4) vs (5.7±0.6)mSv/mGy.cm] and Iodine intake [(6.2±0.9) vs (8.3±1.1)g] of the double low dose scan group were lower than the routine scan group (P<0.001). Conclusion: Spiral CT with low radiation dose and low dose contrast agent can get good picture quality and meet the needs of clinical diagnosis, but also significantly reduce the radiation and iodine intake.
|
|
|
|
|
[1] Mayo J, Thakur Y. Pulmonary CT angiography as first-line imaging for PE: image quality and radiation dose considerations[J].AJR Am Roentgenol, 2013, 200(3):522~528 . [2] 汪玲玲,刘啸峰.肺动脉CTA对诊断肺动脉血栓的应用价值[J].安徽医学,2014,35(4):482~484. [3] Adams DM, Stevens SM, Woller SC, et al. Adherence to PIOPED Ⅱ investigators' recommendations for computed tomography pulmonary angiography[J].Am Med, 2013, 126(1):36~42. [4] 于龙, 高珅,周著.CT增强对比剂致不良反应的分析、预防及处理[J].中国医院用药评价与分析,2013,13(10):935~937. [5] Smith-Bindman R, Lipson J, Marcus R, et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer[J].Arch Intern Med, 2009, 169(22):2078~2086. [6] 祁丽,张龙江,卢光明.双低血管成像的应用现状[J].国际医学放射学杂志,2014,37(2):142~146. [7] ICRP. 111e 2007 recommendations of the International Commission on Radiological Protection (ICRP)[J].Ann ICRP, 2007, 37(2~4): 1~332. [8] 潘锋,祝跃明,吴晓.多层螺旋CT血管成像诊断肺动脉栓塞的价值[J].中国医学影像学杂志,2008,16(1):36~38. [9] 朱红伟,王素娟,王晔.不同浓度造影剂在肺动脉CTA中的应用研究[J].医学影像学杂志,2015,7(4):633~636. [10] Woo JK, Chiu RY, Thakur Y. Risk-benefit analysis of pulmonary CT angiography in patients with suspected pulmonary embolus[J].AJR Am Roentgenol, 2012, 198(6):1332~1339. [11] 周明.肺动脉CTA扫描技术的探讨[J].医学信息,2015,3(11):255~256. [12] Radon MR, Kaduthodil MJ, Jagdish J. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography[J].Clin Radiol, 2011, 66(1):43~49. |
[1] |
. [J]. 河北医学, 2017, 23(3): 526-528. |
|
|
|
|