Study on Relationship between FeNO concentration with Pulmonary Function and Serum IL-17 IgE in Patients with Bronchial Asthma in Non-acute Episodes |
RONG Qing'na, ZHAO Xiaoling, LI Xia, et al |
Langfang People's Hospital, Hebei Langfang 065000, China |
|
|
Abstract Objective: To investigate the relationship between exhaled nitric oxide (FeNO) concentration with pulmonary function and serum interleukin-17 (IL-17) and immunoglobulin E (IgE) levels in patients with bronchial asthma in non-acute episodes. Methods: 125 patients with non-acute bronchial asthma were enrolled according to the Asthma Control Test (ACT) score: control group (40 cases), partial control group (45 cases), and uncontrolled group (40 cases). Another 40 patients with normal physical examination were selected as the control group. FeNO, lung function indexes and serum IL-17 and IgE were detected in several groups of subjects. The results of several groups were compared and the correlation between ACT scores and FeNO, lung function indicators, IL-17, and IgE was analyzed. Results: Compared with the control group, the level of FeNO in the experimental group was significantly higher, the levels of FEV1 and PEF were significantly lower (P<0.05); In the experimental group, compared with the uncontrolled group, the level of FeNO in the control group was significantly lower, the levels of FEV1 and PEF were significantly higher, and the level of FeNO in the control group was significantly lower, and the levels of FEV1 and PEF were significantly higher than those in the control group (P<0.05). The levels of FEV1 and PEF in some control group were close to those in uncontrolled group (P>0.05); the levels of IL-17 and IgE in the experimental group were significantly higher than those in the control group (P<0.05); the levels of IL-17 and IgE in the control group and some control group were significantly lower than those in the uncontrolled group, and the levels of IL-17 and IgE in the control group were significantly lower than those in the partial control group (P<0.05). FeNO concentration was not significantly correlated with FEV1 and PEF (P>0.05), but positively correlated with serum levels of IL-17 and IgE (P<0.05). Conclusion: FeNO in patients with bronchial asthma in non-acute episodes is closely related to serum IL-17 and IgE, but has no significant correlation with pulmonary function. FeNO combined with pulmonary function can comprehensively reflect asthma control in patients with bronchial asthma.
|
|
|
|
|
[1] 黄秘,肖卫,张煦.呼出气一氧化氮对哮喘诊断有效性的Meta分析[J].长江大学学报(自科版),2018,15(16):17~25. [2] 陈志营.呼出气一氧化氮测定对支气管哮喘-慢性阻塞性肺疾病重叠综合征患者的诊断价值[J].检验医学与临床,2018,15(18):2803~2805. [3] 李丽,李梅华,任朝凤.呼出气一氧化氮测定在支气管哮喘诊断中的应用价值[J].临床合理用药杂志,2018,11(29):112~113. [4] 杨萍.学龄期中重度哮喘急性发作特征及FeNO与肺功能的相关性[J].西南国防医药,2017,27(12):1295~1298. [5] Hu Y,Chen Z,Jin L,et al. Decreased expression of indolamine 2,3-dioxygenase in childhood allergic asthma and its inverse correlation with fractional concentration of exhaled nitric oxide[J]. Ann Allergy Asthma Immunol,2017,119(5):429~134. [6] 吴国斌,赖庆文,曾省都,等.不同程度老年支气管哮喘呼出一氧化氮水平与肺功能的相关性研究[J].国外医学(医学地理分册),2017,38(04):387~390. [7] 高胜东,郑丽辉,周钊,等.支气管舒张实验与呼出气一氧化氮测定在咳嗽患者诊断中的价值对比研究[J].泰山医学院学报,2018,39(12):1405~1406. [8] 赵晓琴,邢莎莎.呼出气一氧化氮对哮喘-慢性阻塞性肺疾病重叠综合征的临床诊断价值[J].实用医技杂志,2018,25(9):997~998. |
|
|
|