Abstract:Objective: To evaluate the image quality of direct lower extremity venography by 320-row spiral CT under different CT delay time and scanning time, optimize CT machine scanning plan and obtain the best imaging parameters. Methods: 60 patients with suspected inferior vena cava or lower extremity venous diseases were performed direct CT venography of lower extremity with Toshiba 320-row spiral CT. Under the same liquid volume (200ml), contrast medium concentration (1∶7~1∶9) and injection rate of 3.0ml/s, the delay time and scanning time of group A were 50s and 10~20s respectively. In group B, the delay time was 30s and the scanning time was 20~30s. In group C, the delay time was 20 s and the scanning time was 30 ~ 40 s. All the images were sent to the post-processing workstation for VR and MIP reconstruction. The image quality of lower extremity venography was evaluated according to four grades and analyzed statistically. Results: The image quality of each experimental group was not the same. There was no significant difference between group B and group C, and the image quality was good or excellent. There was significant difference between group A and groups B and C, and the image quality was mainly good and fair. Conclusion: Under the condition of the same liquid volume (200ml), contrast medium concentration (1∶7 ~ 1∶9) and injection rate of 3.0ml/s, 320-Row spiral CT direct lower extremity venography can be used to obtain images satisfying clinical diagnostic needs by using delay time 50s and scanning time 20~30s.
曹宏伟, 程艳芬, 王胜林, 万立野, 崔志新, 马飞龙, 邢千超. 延迟时间及扫描时间对320排螺旋CT下肢静脉血管直接造影成像图像质量的影响[J]. 河北医学, 2022, 28(1): 155-158.
CAO Hongwei, CHENG Yanfen, WANG Shenglin, et al. Effect of Delay Time and Scanning Time on the Quality of Direct Lower Extremity Venography by 320-Row Spiral CT. HeBei Med, 2022, 28(1): 155-158.
[1] 王宁,李高阳,张丹,等.探讨不同浓度对比剂对多层螺旋CT直接法下肢静脉成像图像质量的影响[J].河北医学,2018,24(3):482~485. [2] Shi WY,Wang LW,Wang SJ,et al.Combined direct and indirect CT venography (combined CTV) in detecting lower extremity deep vein thrombosis[J].Medicine (Baltimore),2016,95(11):1~7. [3] Uhl,F J.Three-dimensional modelling of the venous system by direct multislice helical computed tomography venography:technique,indications and results[J].Phlebology,2012,27(6):270~288. [4] 焦慧,张丽娟,亓恒涛,等.CT下肢静脉造影在Klippel-Trenaunay Syndrome诊断中的应用价值[J].医学影像学杂志 2020,30(9):1690~1694. [5] 欧阳裕锋,胡秋根,岑玉坚,等.双能量CT直接增强法在双下肢静脉成像中的优势[J].分子影像学杂志,2019,42(1):5~9. [6] 赵君禄,聂关伟,任庆云,等.直接法MSCTV对下肢深静脉梗阻性病变的诊断价值[J].实用放射学杂志,2017,33(6):632~635. [7] 张静,姜建威,殷允娟,等.下肢浅静脉曲张256层螺旋CT低剂量扫描成像研究[J].中国医学影像学杂志,2017,25(4):283~286. [8] 李小龙,李雪萍,杨铁,等.多层螺旋CT直接法下肢静脉CT成像在髂静脉压迫综合征的临床应用价值[J].中国医学装备,2021,18(6):79~82. [9] 李高阳,张丹,吕亮,等.不同注射速率下多层螺旋CT直接法下肢静脉成像髂静脉图像质量的比较[J].CT理论与应用研究,2018,27(3):123~131.